Mar 29, 2018 I going install esxi ibm series server. Want watch this again later sign add this video playlist. Als ibm imm activation key crack export imm outlook downloads. Imm and imm2 support lenovo servers. Comj74ry67 ibm imm activation key crack free download project igi game full version ibmlenovo. Apr 10, 2014 It is how the Advanced IMM is enabled amongst other things. Also, as far as I am aware, you do not need to shut down the server to activate the FoD, just log into the IMM (you have configured IMM, haven't you?) and add the key that you downloaded from the IBM FoD website. There is also a RedBook on FoD published in Oct 2012.
Abstract
This document lists which Lenovo System x, NeXtScale, Flex System, and BladeCenter servers support the Integrated Management Module II (IMM2) service processor and the older Integrated Management Module (IMM) service processor.
The IMM and IMM2 consolidate service processor functionality previously provided by the combination of the Baseboard Management Controller (BMC) and the Remote Supervisor Adapter II in System x and BladeCenter products.
Introduction
This document lists which Lenovo System x, NeXtScale, Flex System, and BladeCenter servers support the Integrated Management Module II (IMM2) service processor and the older Integrated Management Module (IMM) service processor.
The IMM and IMM2 consolidate service processor functionality previously provided by the combination of the Baseboard Management Controller (BMC) and the Remote Supervisor Adapter II in System x and BladeCenter products.
The IMM2 operates independently of the installed operating system.
Integrated Management Module II
Integrated Management Module II (IMM2) is the second-generation management module integrated on System x servers. IMM2 offers three levels of functionality: Basic, Standard, and Advanced.
Upgrading to Standard or Advanced will be performed using a software license key using Lenovo Features on Demand (FoD).
IMM2 Basic has the following features:
- Industry-standard interfaces and protocols
- Intelligent Platform Management Interface (IPMI) Version 2.0
- Common Information Model (CIM)
- Advanced Predictive Failure Analysis (PFA) support
- Continuous health monitoring
- Choice of a dedicated or shared Ethernet connection
- Supports secure SSH text console access with optional encryption capabilities using AES cyphers
- Domain Name System (DNS) server support
- Dynamic Host Configuration Protocol (DHCP) support
- Embedded Dynamic System Analysis (DSA)
- LAN over USB for in-band communications to the IMM
- Serial over LAN
- Server console serial redirection
- Remote firmware updating
- Remote configuration through Advanced Settings Utility (ASU)
Note: IMM2 Basic does not include web browser or remote presence capabilities.
IMM2 Standard (as standard in some servers or as enabled using the Features on Demand software license key in other servers) has the following features:
- Secure web server user interface
- Remote power control
- Access to server vital product data (VPD)
- Advanced Predictive Failure Analysis (PFA) support
- Power Management
- Automatic notification and alerts
- Continuous health monitoring and control
- Choice of a dedicated or shared Ethernet connection
- Domain Name System (DNS) server support
- Dynamic Host Configuration Protocol (DHCP) support
- E-mail alerts
- Syslog logging support
- Embedded Dynamic System Analysis (DSA)
- Enhanced user authority levels
- LAN over USB for in-band communications to the IMM
- Event logs that are time stamped, saved on the IMM, and that can be attached to e-mail alerts
- Support for Industry-standard interfaces and protocols: IPMI V2.0, CIM, and SNMP
- OS watchdogs
- Serial over LAN
- Server console serial redirection
- User authentication using a secure connection to a Lightweight Directory Access Protocol (LDAP) server
IMM2 Advanced (as enabled using the Features on Demand software license key) has the following features:
- Remote presence, including remote control of server via a Java or ActiveX client
- Supports up to four concurrent remote users
- Operating system failure screen capture and display through the web interface
- Video recorder and playback function
- Virtual media allowing the attachment of a diskette drive, CD/DVD drive, USB flash drive, or disk image to a server. For servers with an SD Media adapter installed, you can configure volumes on those SD Cards for use by the IMM.
Note: For servers where only IMM2 Basic is installed (for example, x3100 M4, x3250 M4, nx360 M4), the use of IMM2 Advanced requires IMM2 Standard also be purchased and enabled.
The following table lists the IMM2 upgrades.
Note: The IMM2 Advanced upgrade requires the IMM2 Standard upgrade.
Part number | Feature codes | Description |
90Y3900 | A1MK | Integrated Management Module Standard Upgrade |
90Y3901 | A1ML | Integrated Management Module Advanced Upgrade (requires Standard Upgrade, 90Y3900) |
Integrated Management Module
![Key Key](/uploads/1/1/8/9/118994359/869019659.jpg)
In older System x servers, the Integrated Management Module (IMM) consolidates the service processor functionality, Super I/O, video controller, and remote presence capabilities in a single chip on the server system board. The IMM consolidates service processor functionality previously provided in the BMC and the Remote Supervisor Adapter II in System x and BladeCenter products.
Lenovo offers two levels of IMM, Standard and Premium. If the server has IMM Standard functionality, it can be upgraded to IMM Premium by purchasing and installing a Virtual Media Key (either part number 46C7526 or 46C7527, depending on the server) on the server system board. This key is a physical component (Figure 1). However, no new firmware is required. IMM Premium provides Remote Presence and Virtual Media capabilities. Figure 1 shows where the Virtual Media Key is installed in one of the supported servers (x3620 M3).
Figure 1. Installing the Virtual Media Key in the System x3620 M3
IMM Standard has the following features:
- Access to server vital product data (VPD)
- Advanced Predictive Failure Analysis (PFA) support
- Automatic notification and alerts
- Continuous health monitoring and control
- Choice of a dedicated or shared Ethernet connection
- Domain Name System (DNS) server support
- Dynamic Host Configuration Protocol (DHCP) support
- E-mail alerts
- Embedded Dynamic System Analysis (DSA)
- Enhanced user authority levels
- LAN over USB for in-band communications to the IMM
- Event logs that are time stamped, saved on the IMM, and that can be attached to e-mail alerts
- Support for Industry-standard interfaces and protocols: IPMI V2.0, CIM, and SNMP
- OS watchdogs
- Remote configuration through Advanced Settings Utility (ASU)
- Remote firmware updating
- Remote power control
- Secure web server user interface
- Serial over LAN
- Server console serial redirection
- User authentication using a secure connection to a Lightweight Directory Access Protocol (LDAP) server
IMM Premium (as enabled using the Virtual Media Key) adds the following features in addition to the features of IMM Standard:
- Remote presence, including remote control of server
- Operating system failure screen capture and display through the web interface
- Virtual media allowing the attachment of a diskette drive, CD/DVD drive, USB flash drive, or disk image to a server
The following table lists the available Virtual Media Keys and their part numbers. Table 3 lists the key used in each System x server. Note that three different part numbers exist. The parts are keyed to prevent insertion into the wrong system.
Withdrawn: All three part numbers in the table are withdrawn from marketing.
Part number | Description |
46C7526 | Virtual Media Key |
46C7527 | Virtual Media Key for Entry Systems |
49Y7290 | Virtual Media Key for x3100 M3 |
System x server support
System x servers include either the Integrated Management Module II (newer systems) or the Integrated Management Module (older systems).
Integrated Management Module II support
The following table lists the IMM2 service processors that are standard and optional for each System x server. The values in the table have the following meanings:
- Standard: This level of functionality of IMM2 comes standard with the server.
- Upgrade: This level of functionality of IMM2 can be purchased as an option and enabled via Features on Demand using the indicated part number.
- No: The server does not support this level of the IMM2 service processor.
System x server | IMM2 Basic | IMM2 Standard | IMM2 Advanced |
---|---|---|---|
System x3100 M4 | Standard | Upgrade, using 90Y3900 | Upgrade, using 90Y3901* |
System x3100 M5 | Standard | Standard | Upgrade, using 90Y3901 |
System x3250 M4 | Standard | Upgrade, using 90Y3900 | Upgrade, using 90Y3901* |
System x3250 M5 | Standard | Standard | Upgrade, using 90Y3901 |
System x3250 M6 | Standard | Standard | Upgrade, using 90Y3901 |
System x3300 M4 | Standard | Standard | Upgrade, using 90Y3901 |
System x3500 M4 | Standard | Standard | Upgrade, using 90Y3901 |
System x3500 M5 | Standard | Standard | Upgrade, using 90Y3901 |
System x3530 M4 | Standard | Standard | Upgrade, using 90Y3901 |
System x3550 M4 | Standard | Standard | Upgrade, using 90Y3901 |
System x3550 M5 | Standard | Standard | Upgrade, using 90Y3901 |
System x3630 M4 | Standard | Standard | Upgrade, using 90Y3901 |
System x3650 M4 | Standard | Standard | Upgrade, using 90Y3901 |
System x3650 M4 BD | Standard | Standard | Upgrade, using 90Y3901 |
System x3650 M4 HD | Standard | Standard | Upgrade, using 90Y3901 |
System x3650 M5 | Standard | Standard | Upgrade, using 90Y3901 |
System x3750 M4 | Standard | Standard | Standard |
System x3850 X6 | Standard | Standard | Standard |
System x3950 X6 | Standard | Standard | Standard |
iDataPlex dx360 M4 | Standard | Standard | Upgrade, using 90Y3901 |
NeXtScale nx360 M4 | Standard | Upgrade, using 90Y3900 | Upgrade, using 90Y3901* |
NeXtScale nx360 M5 | Standard | Upgrade, using 90Y3900 | Upgrade, using 90Y3901* |
* For systems with only IMM2 Basic standard, the IMM2 Advanced upgrade requires IMM2 Standard (90Y3900) also be purchased and enabled.
Integrated Management Module support
The following table lists the IMM offerings that are standard and optional for each System x server. The values in the table have the following meanings:
- Standard: This IMM comes standard with the server.
- Upgrade: This IMM functionality can be purchased as an option via the Virtual Media Key (VMK) explained using the indicated part number.
- No: The server does not support this version of the IMM service processor.
System x server | IMM Standard | IMM Premium (VMK) | BMC |
System x3100 M3 | Standard | Upgrade, using 49Y7290 | No |
System x3200 M3 | Standard | Upgrade, using 46C7527 | No |
System x3250 M3 | Standard | Upgrade, using 46C7527 | No |
System x3400 M2, M3 | Standard | Upgrade, using 46C7527 | No |
System x3500 M2, M3 | Standard | Standard | No |
System x3550 M2, M3 | Standard | Upgrade, using 46C7526 | No |
System x3620 M3 | Standard | Upgrade, using 46C7527 | No |
System x3630 M3 | Standard | Upgrade, using 46C7527 | No |
System x3650 M2, M3 | Standard | Upgrade, using 46C7526 | No |
System x3690 X5 | Standard | Standard | No |
System x3755 M3 | No | No | Standard* |
System x3850 X5 | Standard | Standard | No |
System x3950 X5 | Standard | Standard | No |
iDataPlex dx360 M2 | Standard | Upgrade, using 46C7527 | No |
iDataPlex dx360 M3 | Standard | Upgrade, using 46C7527 | No |
* The x3755 M3 includes an Aspeed AST-2050 Baseboard Management Controller (BMC). This BMC is different from the BMCs in earlier servers and includes the IMM Premium feature set.
Flex System compute node support
Flex System compute nodes include the Integrated Management Module II and all have IMM2 Advanced enabled.
Compute node | IMM2 Basic | IMM2 Standard | IMM2 Advanced |
---|---|---|---|
Flex System x220 (7906) | Standard | Standard | Standard |
Flex System x222 (7916) | Standard | Standard | Standard |
Flex System x240 (8737) | Standard | Standard | Standard |
Flex System x240 (7162) | Standard | Standard | Standard |
Flex System x240 M5 (9532) | Standard | Standard | Standard |
Flex System x440 (7917) | Standard | Standard | Standard |
Flex System x440 (7167) | Standard | Standard | Standard |
Flex System X6 (7903) | Standard | Standard | Standard |
Flex System X6 (7196) | Standard | Standard | Standard |
BladeCenter server support
The BladeCenter Management Module (MM) and Advanced Management Module (AMM) are the central points of management for the BladeCenter chassis. As such, when the AMM is not responsive, the ability to perform normal management on the chassis is significantly compromised. The AMM is Version 2 of the MM. The main differences are that the AMM is USB based (instead of PS/2) and also has a feature to save service data. The service data collects most of the useful information that is required to support the AMM.
Each BladeCenter chassis, with the exception of the BladeCenter S, supports a redundant pair of management modules. The two management modules used in a chassis must be identical.
The MM/AMM is used to monitor, manage, configure, report logs, and update firmware from BladeCenter chassis blades and I/O modules. Although the IMM is now included in some blade servers, the AMM remains the management module for systems-management functions for BladeCenter and blade servers. There is no external network access to the IMM on blade servers. The AMM must be used for remote management of blade servers. The IMM replaces the functionality of the BMC and the Concurrent Keyboard, Video, and Mouse (cKVM) option card in past blade server products:
- The Advanced Management Module for BladeCenter S, BladeCenter E, BladeCenter H, and BladeCenter HT is part # 25R5778.
- The Advanced Management Module for BladeCenter T is part # 32R0835.
- The original MMs have been withdrawn but were only supported in BladeCenter E (BC-E, part # 48P7055) and BladeCenter T (BC-T, part # 90P3741).
All BladeCenter chassis models with the original MM installed can be upgraded to an AMM. In fact, most current servers require that the chassis have AMMs installed.
The following table lists the service processors that are standard and optional in each BladeCenter chassis.
Ibm Imm Configuration
Table 6. Management models standard in each BladeCenter chassis
BladeCenter chassis | Management Module (MM) | Advanced Management Module (AMM) |
BladeCenter E, machine types 8667, 1881, 7967, 8760 | Some models have the MM standard. Some models have the AMM standard. | |
BladeCenter T, machine types 8267, 8720, 8730 | Some models have the MM standard. Some models have the AMM standard. | |
BladeCenter H, machine types 8852,1886, 7989 | No | Standard |
BladeCenter HT, machine types 8740, 8750 | No | Standard |
BladeCenter S, machine types 8886,1948, 7779 | No | Standard |
The following table lists the service processors that are standard for each of the currently available BladeCenter servers. For older servers, see the Lenovo Press document, Service Processors Supported in System x Servers, available from:
http://lenovopress.com/tips0146
http://lenovopress.com/tips0146
Table 7. Service processors in BladeCenter servers
![Ibm Ibm](/uploads/1/1/8/9/118994359/265848128.gif)
Blade Server | IMM Standard | IMM Premium | IMM2 Advanced | BMC |
HS22 | Standard | No | No | No |
HS22V | Standard | No | No | No |
HS23E | No | No | Standard | No |
HS23 | No | No | Standard | No |
HX5 | Standard | No | No | No |
LS22 | No | No | No | Standard |
LS42 | No | No | No | Standard |
Useful links
These web pages provide addition information about the service processors in System x and BladeCenter servers:
- Lenovo Press paper Using System x Features on Demand
http://lenovopress.com/redp4895 - IBM Features on Demand web site
https://fod.lenovo.com/lkms - ServerProven
http://www.lenovo.com/us/en/serverproven/xseries/upgrades/smmatrix.shtml - IMM2 User's Guide
http://publib.boulder.ibm.com/infocenter/systemx/documentation/topic/com.lenovo.sysx.imm2.doc/printable_doc.html - IMM User's Guide
http://ibm.com/support/entry/portal/docdisplay?lndocid=MIGR-5079770 - MM and AMM User's Guide
http://ibm.com/support/entry/portal/docdisplay?lndocid=MIGR-5073887 - MM and AMM Command Line Reference Guide
http://ibm.com/support/entry/portal/docdisplay?lndocid=MIGR-54667 - Lenovo Press document Service Processors Supported in System x Servers, covering Netfinity and xSeries as well as the first generation of System x servers
http://lenovopress.com/tips0146
Related product families
Product families related to this document are the following:
Trademarks
Ibm Imm Activation Key Management
Lenovo and the Lenovo logo are trademarks or registered trademarks of Lenovo in the United States, other countries, or both. A current list of Lenovo trademarks is available on the Web at https://www.lenovo.com/us/en/legal/copytrade/.
The following terms are trademarks of Lenovo in the United States, other countries, or both:
Lenovo®
Advanced Settings Utility
BladeCenter®
Dynamic System Analysis
Flex System
NeXtScale
Netfinity®
System x®
X5
iDataPlex®
xSeries®
Lenovo®
Advanced Settings Utility
BladeCenter®
Dynamic System Analysis
Flex System
NeXtScale
Netfinity®
System x®
X5
iDataPlex®
xSeries®
The following terms are trademarks of other companies:
ActiveX® is a trademark of Microsoft Corporation in the United States, other countries, or both.
Ibm Imm Activation Key 2017
Other company, product, or service names may be trademarks or service marks of others.
Ibm Imm Activation Key Free
The integrated management module (IMM) is a second generation of the functions that were formerly provided by the baseboard management controller hardware. It combines service processor functions, video controller, and remote presence function in a single chip.
Ibm Imm Activation Key File
The IMM supports the following basic system management features:
- Environmental monitor with fan speed control for temperature, voltages, fan failure, and power supply failure.
- Light path diagnostics LEDs indicators to report errors that occur with fans, power supplies, microprocessor, hard disk drives, and system errors.
- DIMM error assistance. The Unified Extensible Firmware Interface (UEFI) disables a failing DIMM that is detected during POST, and the IMM lights the associated system error LED and the failing DIMM error LED.
- System event log (SEL).
- ROM-based IMM firmware flash updates.
- Auto Boot Failure Recovery (ABR).
- A virtual media key, which enables remote presence support (remote video, remote keyboard/mouse, and remote storage).
- Automatic microprocessor disable on failure and restart in a two-microprocessor configuration when one microprocessor signals an internal error.
- Nonmaskable interrupt (NMI) detection and reporting.
- Automatic Server Restart (ASR) when POST is not complete or the operating system hangs and the operating system watchdog timer times-out. The IMM might be configured to watch for the operating system watchdog timer and reboot the system after a timeout, if the ASR feature is enabled. Otherwise, the IMM allows the administrator to generate a nonmaskable interrupt (NMI) by pressing an NMI button on the light path diagnostics panel for an operating-system memory dump. ASR is supported by IPMI.
- Intelligent Platform Management Interface (IPMI) Specification V2.0 and Intelligent Platform Management Bus (IPMB) support.
- Invalid system configuration (CNFG) LED support.
- Serial port redirection over telnet or ssh.
- Serial over LAN (SOL).
- Active Energy Manager
- Query power-supply input power.
- PECI 2 support.
- Power/reset control (power-on, hard and soft shutdown, hard and soft reset, schedule power control).
- Alerts (in-band and out-of-band alerting, PET traps - IPMI style, SNMP, e-mail).
- Operating-system failure blue screen capture.
- Command-line interface.
- Configuration save and restore.
- PCI configuration data.
- Boot sequence manipulation.
The IMM also provides the following remote server management capabilities through the OSA SMBridge management utility program:
Ibm Imm Update
- Command-line interface (IPMI Shell): The command-line interface provides direct access to server management functions through the IPMI 2.0 protocol. Use the command-line interface to issue commands to control the server power, view system information, and identify the server. You can also save one or more commands as a text file and run the file as a script.
- Serial over LAN: Establish a Serial over LAN (SOL) connection to manage servers from a remote location. You can remotely view and change the UEFI settings, restart the server, identify the server, and perform other management functions. Any standard Telnet client application can access the SOL connection.